50 kVA generator set
A 50 kVA generator set is a high-power diesel unit designed for continuous operation in industrial, construction, agricultural, and hospitality settings, as well as for providing backup power to critical facilities that cannot afford a power outage.
Genergy's GDS diesel generator series, with a power range of approximately 50 kVA, ranges from 27 to 94 kVA. It is three-phase (400/230 V), features a 1,500 RPM engine, a copper alternator, a Deep Sea controller, a soundproof enclosure, and is equipped for automatic transfer switch (ATS) operation. It includes a low-emission EUV (Stage V) version.
- 27 – 94 kVAen torno a 50 kVA
- 1500 RPMmotor diésel
- Trifásico400/230V
- ATS · EUVrespaldo y Stage V
Genergy's In-House Manufacturing and After-Sales Service · 2026 Catalog
GDS 50 kVA Generator Sets
Three-phase diesel generator series ranging from 27 to 94 kVA, soundproofed and equipped for automatic start-up. Filter by power output based on your installation.
What is a 50 kVA generator set?
A 50 kVA generator set is a high-power diesel unit (with an effective output of around 40 kW) consisting of an engine and an alternator, capable of providing an independent power supply to an industrial facility, a construction site, a farm, or a facility with high power consumption. kVA refers to apparent power; the actual effective power in kW is slightly lower, depending on the power factor.
It serves as the primary power source in areas not connected to the grid or as a backup that starts automatically in the event of a power outage. At this power rating, Genergy operates on a three-phase system (400/230 V) with a diesel engine running at 1,500 RPM for continuous and intensive use, features a soundproof enclosure, and, in the EUV version, is equipped with a Stage V low-emission engine for regulated areas.
How much power do you need?
Guideline. The exact power rating depends on the connected equipment, its startup peaks, and hours of use. Add up the power consumption and include a 20–30% margin. Tell us about your situation, and we’ll help you select the right equipment.
| Type of installation / use | Approximate power | GDS Models |
|---|---|---|
| Small-scale industry, agriculture, large-scale commerce | 27 – 47 kVA | GDS27T · GDS50T |
| Industrial, construction, hospitality, regulated areas (Stage V) | 55 kVA | GDS55T EUV |
| High consumption, extensive support, continuous use | 69 – 94 kVA | GDS70T · GDS90T |
Key Features
1,500 RPM diesel engine
Less wear, lower fuel consumption, and longer service life—ideal for continuous and intensive use.
Copper Alternator
Synchronous alternator with 100% copper windings and low distortion for stable current.
Deep Sea Controller
A control unit that monitors parameters, alerts users to anomalies, and protects the equipment.
ATS-Ready
Ready for automatic startup in the event of a power failure (requires a transfer switch).
EUV Version (Stage V)
The GDS55T EUV is equipped with a low-emission engine, making it suitable for areas with environmental regulations.
Soundproofed body
Soundproof cabin that reduces noise and provides protection from the elements.
Solar-compatible
Inverter-compatible dry contact: functions as a photovoltaic backup generator.
Genergy Total Warranty
3-year warranty covering labor, transportation, and replacement parts, with in-house after-sales service.
Features, Benefits, and Integrations
Features
- Generate approximately 40 kW of continuous power
- Serve as the primary power source or as a backup in the event of a power outage
- Supplying food to an industrial facility, construction site, or farm
- Automatically restart after a power outage (with ATS panel)
- Supply three-phase power (400V) to machinery
Benefits
- Electrical Continuity in Demanding Environments
- Long range and low diesel consumption at 1,500 RPM
- Consistent performance during long workdays
- Low noise level thanks to the bodywork
- Stage V option for areas with regulations
Integrations
- ATS Transfer Panels for Automatic Start-up
- Solar inverters and photovoltaic systems (dry contact)
- Three-phase industrial systems
- Machinery, pumps, and high-consumption equipment
- Scheduled Timing and Remote Start via Signal
Model Comparison
The GDS diesel series with a capacity of around 50 kVA.
| Model | Power (kVA) | Power (kW) | Voltage | Notes |
|---|---|---|---|---|
| GDS27T | 27 kVA | 22 kW | 400/230V | Three-phase · soundproofed |
| GDS50T | 47 kVA | 38 kW | 400/230V | Three-phase · soundproofed |
| GDS55T EUV | 55 kVA | 44 kW | 400/230V | Stage V · Low Emissions |
| GDS70T | 69 kVA | 55 kW | 400/230V | Three-phase · soundproofed |
| GDS90T | 94 kVA | 75 kW | 400/230V | Three-phase · soundproofed |
Uses of a 50 kVA Generator Set
Industry and Factories
Primary or backup power source for machinery and production lines.
Construction and Building
High power on-site without a permanent utility connection.
Agriculture and Livestock
Pumping, irrigation, and equipment for remote farms and facilities.
Hospitality and Events
Kitchens, HVAC, and high-volume installations.
Regulated Areas
EUV Stage V version for areas with emissions restrictions.
Support with ATS
Automatic startup for systems that cannot be shut down.
Genergy Diesel Generators on Video
Videos of Genergy's GDS diesel series, including the 69 kVA GDS70T from this same series.
Why Buy Your Generator from Genergy
- ✓Manufacturer, not a reseller. Genuine Genergy motor and in-house design, with internal quality control.
- ✓Three-Phase Diesel: 50 kVA Solutions for Industry, Construction, and Agriculture.
- ✓3-Year Comprehensive Warranty: Includeslabor, transportation, and replacement parts.
- ✓In-house After-Sales Service: Technical support and replacement parts directly from the manufacturer.
- ✓Dealer Network: Retail locationsand consultation services throughout Spain.
- ✓Technical Advice: We help you select the right equipment for your facility.
Frequently asked questions
What can a 50 kVA generator power?
It is a high-power generator capable of supplying power to industrial facilities, construction sites, agricultural machinery, the hospitality industry, or high-consumption facilities, with multiple pieces of equipment running at the same time. The exact amount depends on power consumption and the startup peaks of motors and compressors.
How many kW is 50 kVA?
kVA represents apparent power, and kW represents useful active power; with a power factor of 0.8, about 50 kVA is equivalent to about 40 kW. When sizing a system, what matters is the actual power consumption (kW) of the installation.
What is the EUV (Stage V) version?
The GDS55T EUV is equipped with a low-emission engine that complies with European Stage V regulations, designed for use in areas with environmental restrictions, such as urban construction sites or regulated areas.
Why diesel at 1,500 RPM?
The diesel engine at 1,500 RPM operates at a lower speed: less vibration and wear, lower fuel consumption, and a longer service life. It is the ideal choice for continuous and intensive operation, which is common in industry.
Do they have automatic start-stop (ATS)?
They are equipped for automatic startup in the event of a power outage via an ATS transfer switch, so they start up on their own during an outage and restore power within seconds.
Do I need more or less power?
Para potencias menores mira el grupo electrógeno de 20 kVA o el de 10 kVA; para instalaciones industriales de mayor consumo, el generador de 100 kVA o la gama industrial (hasta 358 kVA).
Do you offer a warranty and technical support?
Yes. Genergy is a manufacturer that offers a 3-year comprehensive warranty (covering labor, travel, and replacement parts), its own after-sales service, and a network of distributors throughout Spain.
The recommended power ratings are approximate and depend on each installation. The ATS panel may not be included, depending on the model.
Learn more on the blog
¿No sabes qué 50 kVA elegir?
Dinos qué vas a conectar y las horas de uso, y nuestro equipo técnico te recomienda el modelo GDS con la potencia adecuada. Garantía Total 3 años y postventa propia Genergy.