10 kVA, 8 kW, 230 V
-
10KVA 8KW 400/230V
-
14 kVA, 11 kW, 230 V
-
14KVA 11KW 400/230V
-
20 kVA, 16 kW, 230 V
-
20KVA 16KW 400/230V
-
27 kVA, 22 kW, 230 V
-
27KVA 22KW 400/230V
-
47KVA 37KW 400/230V
-
127KVA 101KW 400/230V
-
275KVA 220KW 400/230V
Industrial Generators: Generator Sets for Businesses Ranging from 10 to 358 kVA
You don't buy an industrial generator based on watts—you buy it based on how many hours it can run continuously and the cost of a shutdown. Here are Genergy’s 17 GDS diesel generator sets, running at 1,500 rpm, soundproofed, with a Deep Sea control panel and an automatic transfer switch rated from 63 to 630 A, plus the two three-phase gasoline models rated at 15 and 18 kW for small businesses. And here’s what you need to know to make the right choice: continuous or standby power, single-phase or three-phase, and how many kVA your business needs.
-
10 kVA, 8 kW, 230 V
-
10KVA 8KW 400/230V
-
14 kVA, 11 kW, 230 V
-
14KVA 11KW 400/230V
-
15 kW 400 V / 3 × 5,000 W 230 VELECTRIC START – IP67
-
20 kVA, 16 kW, 230 V
-
20KVA 16KW 400/230V
-
18 kW 400 V / 3 × 6,000 W 230 VELECTRIC START – IP67
-
27 kVA, 22 kW, 230 V
-
27KVA 22KW 400/230V
-
47KVA 37KW 400/230V
-
55KVA 44KW 400/230V
-
69KVA 55KW 400/230V
-
94KVA 75KW 400/230V
-
127KVA 101KW 400/230V
-
158KVA 123KW 400/230V
-
204KVA 163KW 400/230V
-
275KVA 220KW 400/230V
-
358KVA 286KW 400/230V
What is an industrial generator, and how does it differ from a commercial one?
A professional generator is taken to the job site, runs for a few hours, and is returned to the van. An industrial generator is installed, connected to the power supply, and must be ready to start automatically at 3:00 a.m. when the grid fails, or to run eight hours a day for months on end. This changes the engine (diesel at 1,500 rpm instead of gasoline at 3,000), the alternator (rated for continuous load), the control system (a control unit that manages start-up, shutdown, alarms, and the transfer switch), and how it’s selected: based on continuous power and operating hours, not peak power.
In Genergy, The "industrial" line is the GDS series: diesel generator sets ranging from 10 to 358 kVA, available in single-phase and three-phase models, with soundproofing included as standard. For small businesses that need three-phase power but don't require a diesel generator (such as a workshop, farm, or bakery), there are also the Big Series Generator 15- and 18-kW three-phase generators. If you're looking for a generator to power tools on a construction site, this is the page for you Professional; if you're looking for the one with the highest wattage, generators rated at 12,000 W or more.
- 10 – 358 kVA, 17 GDS diesel generator sets
- 1,500 rpm motorrated for thousands of hours
- ATS 63 – 630Automatic Startupin Case of Power Outage
- Deep Seacentralitaacross the entire product line
- Euro 5GDS55T-EUVfor construction sites with a trailer
- SAT in Spain: In-House Implementation and Replacement
Continuous or standby power: the factor that determines an industrial generator
Generators are rated at two different power levels, and buying the wrong one is the most costly mistake you can make in this category.
PRP · continuous power (prime)
The power the unit can continuously deliver, hour after hour, under varying loads. This is the rating for a generator used in: an off-grid warehouse, a farm, an irrigation pump, or a workshop. A GDS10 delivers 9 kVA (7.2 kW) continuously.
LTP · Standby Power
The maximum output it can provide for a limited time each year, typically as an emergency backup. This is the figure for a standby generator: it starts up when the grid fails and shuts down when power is restored. The GDS10 itself provides 10 kVA of backup power.
The Ruler
If the generator set is going to be the sole power source, size it based on PRP and operate it at 50–80% load. If it is going to serve as a backup to the grid, size it based on LTP with a margin for starting the largest motors (multiply their power by 2.5–3). If you’re unsure, send us your electricity bill and the nameplates: we’ll calculate it for you.
kVA is the apparent power delivered by the generator set; kW is the power consumed by your equipment. For mixed commercial loads, kW ≈ kVA × 0.8.
How many kVA does your company need? Guidelines by Business Type
| Type of company | What to Feed | Order of magnitude | Models Genergy | Mono / Tri |
|---|---|---|---|---|
| Retail, small office, medical office | Lighting, IT, small-scale HVAC, POS systems | 8 – 15 kVA | GDS10M · GDS14M | Single-phase |
| Bar, restaurant, bakery, pastry shop | Cold storage rooms, ovens, ventilation, lighting | 15 – 30 kVA | GDS14 · GDS20 · GDS27 (M or T) | Depending on the installation |
| Workshop, carpentry shop, small-scale manufacturing | Three-phase machines, compressor, lighting | 15 – 50 kVA | Izoard-S · Stelvio-S (gasoline) · GDS20T · GDS27T · GDS50T | Three-phase |
| Agricultural or livestock farm | Milking, ventilation, pumps, cameras | 20 – 70 kVA | GDS20 · GDS27 · GDS50T · GDS70T | Depending on the installation |
| Major construction project, rental property, event with a stage | Cranes, machinery, booths, lighting | 50 – 130 kVA | GDS55T-EUV (with trailer) · GDS90T · GDS130T | Three-phase |
| Industrial building, supermarket, residential building | Manufacturing, industrial refrigeration, elevators, air conditioning | 90 – 200 kVA | GDS90T · GDS130T · GDS150T · GDS200T | Three-phase |
| Factory, hospital, data center, large facility | The entire system with automatic backup | 200–358 kVA (or multiple units) | GDS200T · GDS275T · GDS350T | Three-phase |
Typical orders of magnitude to guide the initial discussion, not a sizing calculation: each installation is calculated based on its contracted power, start-up cycles, and operating hours. For capacities above 358 kVA, the system is analyzed using multiple parallel units or as a custom project.
1,500 or 3,000 rpm, diesel or gasoline: why the industrial engine runs at half speed
| 1,500 rpm Diesel Generator Set (GDS) | 3,000 rpm Gasoline Generator (Three-Phase Big Series) | |
|---|---|---|
| What is it for? | Continuous operation, fixed installation backup, over 20 kVA | Small business with occasional three-phase power, 3- to 8-hour workdays, moving it between locations |
| Service life | Thousands of hours: the engine runs at half speed and experiences less wear and tear | Hundreds to a few thousand hours: gasoline engine at high RPM |
| Power Consumption per kVA | Lower: Diesel at 1,500 rpm is the most efficient under continuous load | Higher per kVA, but with no initial investment in a generator set |
| Noise | 70–75 dB at 7 m, soundproofed as standard | 68–74 dB at 7 m, in open space |
| Automatic Start | Standard equipment: Deep Sea control unit compatible with ATS panel | Optional on ATS models; not available on Izoard-S/Stelvio-S |
| Mobility | Fixed or trailer-mounted (GDS55T-EUV with TRO-GDS55T-EUV) | It has wheels and fits in a van |
| Choose… | If the generator is part of the company's facility | If the generator is just another tool for the company |
Catalog entry 2026. See the model table below for details on each one.
The 19, per kVA
Standby power (LTP) and continuous power (PRP) for diesel engines; maximum and rated power for gasoline engines. All GDS units: 1,500 rpm, soundproofed, Deep Sea control unit, ATS-ready.
| Model | Type | Reservation · continued | Current | dB at 7 m | Deposit | For |
|---|---|---|---|---|---|---|
| GDS10M · GDS10T | Diesel 1,500 rpm · single / triple | 10 kVA · 9 kVA (7,2 kW) | 13 A (T) | 70 | — | Retail, office, large house with ATS |
| GDS14M · GDS14T | Diesel 1,500 rpm · single / triple | 14 kVA · 13 kVA (10,4 kW) | 20 A (T) | 72 | — | Small hospitality business, office |
| Izoard-S | Gasoline 3,000 rpm · tri | 18.5 kVA · 14 kW (rated) | — | 68-74 | 50 L | Workshop with a three-phase machine, construction site |
| GDS20M · GDS20T | Diesel 1,500 rpm · single / triple | 20 kVA · 18 kVA (14,4 kW) | 27 A (T) | 72 | — | Restaurant, bakery, community |
| Stelvio-S | Gasoline 3,000 rpm · tri | 22.5 kVA · 17 kW (rated) | — | 68-74 | 50 L | Mobile light industry, events |
| GDS27M · GDS27T | Diesel 1,500 rpm · single / triple | 27 kVA · — | — | — | — | Farm, workshop, rural inn |
| GDS50T | Diesel 1,500 rpm · 3-cylinder | 47 kVA · — | — | — | — | Light industry, pumping, small supermarket |
| GDS55T-EUV | Diesel 1,500 rpm · 3-cylinder · Euro 5 | 55 kVA (44 kW) · — | — | — | — | Construction and Rental: with TRO-GDS55T-EUV Construction Trailer |
| GDS70T | Diesel 1,500 rpm · 3-cylinder | 69 kVA · — | — | — | — | Large-scale farming, light industry |
| GDS90T | Diesel 1,500 rpm · 3-cylinder | 94 kVA · — | — | — | — | Warehouse, residence, supermarket |
| GDS130T | Diesel 1,500 rpm · 3-cylinder | 127 kVA · 115 kVA (92 kW) | 166 A | 75 | 200 L | Industrial building |
| GDS150T | Diesel 1,500 rpm · 3-cylinder | 158 kVA · 140 kVA (112 kW) | 202 A | 75 | 200 L | Industry, small hospital |
| GDS200T | Diesel 1,500 rpm · 3-cylinder | 204 kVA · 185 kVA (148 kW) | 267 A | 75 | 390 L | Large facility |
| GDS275T | Diesel 1,500 rpm · 3-cylinder | 275 kVA · 250 kVA (200 kW) | 361 A | 75 | 400 L | Factory, Data Center |
| GDS350T | Diesel 1,500 rpm · 3-cylinder | 358 kVA · 325 kVA (260 kW) | 469 A | 75 | 800 L | The largest in the lineup |
Catalog Information Genergy 2026. The "—" are filled in with the specifications for each model (fuel consumption at 25/50/75/100%, range, weight, dimensions); price and warranty are listed in the specifications. The GDS130T through GDS350T models are equipped with a water-cooled turbocharged engine.
Automatic Start-up, ATS Panel, and Commissioning
Deep Sea DSE7320 Control Unit
Across the entire GDS family. It detects a power outage, starts the generator, transfers the load, and restores power once the grid becomes stable again. Scheduled startup, via external signal, and remote communication. It is the industry standard—not proprietary electronics that only the manufacturer can repair.
Transfer panel rated from 63 to 630 A
Seven ATS panels (63, 80, 100, 125, 250, 400, and 630 A) from the same manufacturer as the unit, tested together. The installer sizes them based on the actual service connection. Details and operation during automatic startup.
Commissioning at the Facility
Large GDS units come with a startup service (each model has its own catalog reference): a technician inspects the installation, starts the unit under load, and leaves the control panel programmed. This is not an extra service you need to seek elsewhere.
Replacement Parts by Part Number
Air, oil, and fuel filters with their own model-specific part numbers in the catalog. Scheduled maintenance isn't about finding the part—it's about ordering it.
Hybrid or Battery-Powered Industrial Generator? How Genergy Does It
More and more companies are looking for a "hybrid generator": one that doesn't require the generator set to start up for every peak load and that reduces engine operating hours. Genergy It doesn't sell a product with that name; it sells the combination that makes it happen.
Generator Set + Battery-Powered Inverter
The inverter powers the system from the batteries (charged by the grid or by solar panels) and starts the generator via a dry contact only when the voltage drops. The generator runs at full load just long enough to recharge the batteries and then shuts down. Fewer engine hours, less noise, less diesel. The 17 GDS models support this start-up method. See details under “Photovoltaic Backup System.”
Group + Power Station
For small, sensitive loads (computers, communications), a portable power station acts as a UPS, and the generator kicks in only when the power outage lasts longer. No installation required.
When It Doesn't Make Sense
If the load is continuous and industrial (manufacturing, refrigeration), the battery only adds to the cost: the generator set will operate the same way. In this case, the key factors are sizing based on PRP and proper maintenance.
Why Choose a Genergy Industrial Generator?
Manufacturer with a tax identification number (SAT) in Spain
Engine, alternator, control unit, and switch panel all from the same supplier, with part numbers provided and in-house technicians. When an industrial unit comes to a standstill, the cost lies in the downtime, not the part: the speed of the technical support service is the key factor.
1,500 rpm standard
The entire GDS family runs at 1,500 rpm: half the wear and tear of a 3,000 rpm model and lower consumption per kVA. There are no "economy" versions running at 3,000 rpm in the diesel lineup.
Soundproofed from 70 to 75 dB
Soundproofed enclosure included as standard: it can be installed next to an office, a hotel, or a residence without the need for any civil engineering work related to soundproofing.
5 euros for public works
The GDS55T-EUV complies with the Euro 5 emissions standards required for public works and construction projects, and comes with its own job site trailer.
Custom Project
For a single group or in facilities with multiple service connections, we review the project: group parallel configuration, panels, and commissioning. Send us the installation plans.
Dealer Network
It is purchased and installed through authorized dealers throughout Spain, with the manufacturer providing after-sales service.
Industrialists on Video
Only videos created by Genergy; if any of them do not exist, the card is withdrawn.
Why Buy Your Industrial Generator from Genergy
- 🇪🇸Spanish brandDesign, development, and quality control of Genergy, a manufacturer since 2007.
- 🛡️Warranty: The warranty period for each model is listed on its product page.
- 🔧SAT in Spain: Installation, maintenance, and replacement parts listed by model.
- 📐We work with you to determine the right size. Based on your contracted power and starting loads, we'll tell you the kVA rating, single-phase/three-phase, and ATS.
Frequently Asked Questions About Industrial Generators for Businesses
What is an industrial generator?
How much does an industrial generator cost?
How much power does a business need?
Where can I buy industrial generators in Spain?
What is the difference between continuous power (PRP) and reserve power (LTP)?
Why 1,500 rpm and not 3,000?
Single-phase or three-phase for my business?
Can it start on its own when the power goes out?
What is a hybrid industrial generator, and does Genergy offer one?
Do I need a Euro 5 generator?
Do you design generator set projects for industrial clients?
What kind of maintenance does an industrial complex need?
Learn more on the blog
How much power does a generator set consume?
Liters per hour based on load and kVA.
Gasoline or dieselHow much fuel does a gasoline or diesel generator consume?
The comparison by hour and by kVA.
PowerHow Much Generator Power Does a House Need?
The sum-and-margin method, as applied to a business.
Verified URLs (post-sitemap.xml, Sept. 11, 2026). There are no posts about PRP/LTP or 1,500 vs. 3,000 rpm: gap noted.
What kind of team does your company need?
Please send us your contracted power, the number of machines that start up at the same time, and whether you want automatic backup or continuous operation. We’ll respond via the contact form with the kVA rating, single- or three-phase power, the ATS panel, and the nearest distributor. Technical service in Spain.